DocumentCode
3691260
Title
Bandwidth measurement of terahertz detector using high electron mobility transistor by heterodyne mixing
Author
Y. Ueda;T. Nukariya;S. Suzuki;M. Asada
Author_Institution
Graduate School of Science and Engineering, Tokyo Institute of Technology
fYear
2015
Firstpage
1
Lastpage
2
Abstract
We measured the bandwidth of a terahertz detector using an InAlAs/InGaAs high-electron-mobility-transistor by heterodyne mixing with UTC-PD and a frequency multiplier as a radio frequency (RF) and local oscillator (LO), respectively. The intensity of the intermediate signal was measured by changing the frequency of UTC-PD, and a very high bandwidth of up to 26 GHz was obtained.
Keywords
"Detectors","HEMTs","Bandwidth","Frequency measurement","Yttrium","Sensitivity","Logic gates"
Publisher
ieee
Conference_Titel
Infrared, Millimeter, and Terahertz waves (IRMMW-THz), 2015 40th International Conference on
ISSN
2162-2027
Electronic_ISBN
2162-2035
Type
conf
DOI
10.1109/IRMMW-THz.2015.7327412
Filename
7327412
Link To Document