DocumentCode :
3697606
Title :
Simulation analysis for the attenuation-spring type damper of the pump-valve composite control system
Author :
Junhua Hu;Chao Wu;Xuyao Mao;Hui Tang
Author_Institution :
Wuhan Second Ship Design and Institute, Wuhan Hubei, China
fYear :
2015
Firstpage :
171
Lastpage :
175
Abstract :
In order to reduce the pressure impact of the pump-valve composite system, the attenuation-spring type damper was utilized in this paper. However the characteristics of pump control system and valve control system are different. The dominated parameters of the attenuation-spring type damper were simulated with AMESIM based on the practical entity model to obtain the best matching parameters. Simulation results indicated that when the attenuation pre-charged pressure were composed of 2MPa and 4MPa, and the attenuation´s volume was about 500cm3, and the equivalent orifice diameter was about 1.5mm, and the spring Type damper´s orifice diameter was about 2mm, it would reduce pressure impact both in the pump control process and valve control process. What´s more, it could reduce cavitation noise in the valve control process. These results provided a useful guideline for the next structure design and experiment.
Keywords :
"Valves","Shock absorbers","Control systems","Process control","Attenuation","Orifices","Springs"
Publisher :
ieee
Conference_Titel :
Fluid Power and Mechatronics (FPM), 2015 International Conference on
Type :
conf
DOI :
10.1109/FPM.2015.7337106
Filename :
7337106
Link To Document :