DocumentCode :
3708367
Title :
Fluctuation and change of partial discharge inception voltage under high humidity for rectangular wire motors
Author :
Toru Wakimoto;Hiroki Kojima;Naoki Hayakawa
Author_Institution :
Department of Electrical Engineering and Computer Science, Nagoya University, Japan
fYear :
2015
Firstpage :
59
Lastpage :
62
Abstract :
This paper aims to clarify the mechanism of fluctuation and change characteristics in the partial discharge inception voltage (PDIV) between motor coils constructed from rectangular wires under high humidity environments. To achieve this, the PDIV at 50Hz after pre-discharge between the coil wires were measured at 90% RH for a motor stator and test pieces, both of which were composed of rectangular wires. Electric field analyses were performed for several contact patterns between the rectangular wires for different values of surface conductivity. As the results, we clarified that the PDIV fluctuation and change in rectangular wire motors under high humidity can be caused by a superposition of the various PDIV characteristics for each contact pattern between the coil wires in the motor.
Keywords :
"Moisture","Oscilloscopes","Chlorine","Copper","Stators"
Publisher :
ieee
Conference_Titel :
Electrical Insulation and Dielectric Phenomena (CEIDP), 2015 IEEE Conference on
Print_ISBN :
978-1-4673-7496-5
Type :
conf
DOI :
10.1109/CEIDP.2015.7351997
Filename :
7351997
Link To Document :