• DocumentCode
    3710596
  • Title

    Numerical methods for detecting DC arc fault in lithium-ion batteries

  • Author

    Amaury Augeard;Tchapo Singo;Philippe Desprez;M´hammed Abbaoui

  • Author_Institution
    Universit? Clermont Auvergne, Universit? Blaise Pascal, EA 4646, LAEPT, BP 10448, F-63000 FERRAND, FRANCE
  • fYear
    2015
  • Firstpage
    39
  • Lastpage
    46
  • Abstract
    In this paper, numerical methods to detect series arc fault in lithium-ion batteries are presented. The arc signals which are required for detecting arc fault are obtained using a test bench on which the Current Interrupt Device (CID) opens dynamically by contact release, associated with a 48 V DC battery pack and a resistor which can deliver a maximum of 1000 A. A comparison between the signals with and without arc is done to detect differences that can be used for arc detection. To isolate the arc signature, several methods are used, among them: the spectral analysis of arc signals using a Fast Fourier Transform (FFT) algorithm and a periodogram, the linear regression (moving average), the arc signals derivative and the filtering techniques. The spectral analysis shows a rise of the signal amplitude at high frequencies while the derivative method and the linear regression, among other things, show the instant when the arcing event occurs. Detection criteria may be set according to the type of method implemented. All of these methods mentioned above can be used to develop an Arc-Fault Circuit Interrupter (AFCI) for lithium-ion batteries.
  • Keywords
    "Batteries","Circuit faults","Voltage measurement","Current measurement","Linear regression","Spectral analysis","Discrete wavelet transforms"
  • Publisher
    ieee
  • Conference_Titel
    Electrical Contacts (Holm), 2015 IEEE 61st Holm Conference on
  • Type

    conf

  • DOI
    10.1109/HOLM.2015.7354952
  • Filename
    7354952