• DocumentCode
    3710910
  • Title

    Evaluation of “PID 1500V Ready” modules: a new test protocol

  • Author

    Benoit Braisaz;Didier Binesti;Khalid Radouane

  • Author_Institution
    EDF R&D - ENERBAT, Moret sur Loing, 77250, France
  • fYear
    2015
  • fDate
    6/1/2015 12:00:00 AM
  • Firstpage
    1
  • Lastpage
    7
  • Abstract
    Service life prediction is one of the most important subjects for solar power plant development and operation. PID (Potential Induced Degradation), as a cause of degradation, needs to be studied. PV modules must be PID evaluated especially in the current frame of increasing the string voltage up to 1500V. In order to measure the resistance to PID, an adequate test must be designed, which could be selective, representative, and reproducible.
  • Keywords
    "Junctions","Moisture","Degradation"
  • Publisher
    ieee
  • Conference_Titel
    Photovoltaic Specialist Conference (PVSC), 2015 IEEE 42nd
  • Type

    conf

  • DOI
    10.1109/PVSC.2015.7355626
  • Filename