Title
The Effectiveness of Specialized IC Packages: Experimental and Monte-Carlo Simulation for Basic Orbits and Spacecraft Shielding
Author
Alexey O. Akhmetov;Georgy S. Sorokoumov;Dmitry V. Bobrovsky;Dmitry V. Boychenko;Alexander Y. Nikiforov;Alexander I. Chumakov;Jean-Charles Thomas;Aleksei U. Maksimov;Nikolay A. Vasilenkov
Author_Institution
Specialized Electron. Syst., Nat. Res. Nucl. Univ. MEPhI, Moscow, Russia
fYear
2015
Firstpage
1
Lastpage
5
Abstract
This paper presents the evaluation results of the specialized ICs packages (100- and 144- ceramic packages) using proton and electron accelerators and Monte-Carlo (forward and reverse/adjoint) simulation. Proton and electron results are verified by forward Monte-Carlo modelling and the packages shielding effectiveness is calculated for a wide- range space radiation environment (5 orbits from low-earth orbit to geostationary orbit) and different spacecraft shielding thicknesses using reverse/adjoint Monte-Carlo method.
Keywords
"Protons","Orbits","Space vehicles","Attenuation","Radiation effects","Solid modeling","Standards"
Publisher
ieee
Conference_Titel
Radiation and Its Effects on Components and Systems (RADECS), 2015 15th European Conference on
Print_ISBN
978-1-5090-0232-0
Type
conf
DOI
10.1109/RADECS.2015.7365674