• DocumentCode
    3721792
  • Title

    The phase sensitivity and response time of an X-band dual channel microwave phase detector

  • Author

    Hao Yan;Xiaoping Liao;Di Hua

  • Author_Institution
    Key Laboratory of MEMS of the Ministry of Education, Southeast University, Nanjing, Jiangsu 210096, China
  • fYear
    2015
  • Firstpage
    1
  • Lastpage
    4
  • Abstract
    An X-band dual channel microwave phase detector is measured at 10GHz with -180° to +180° phase difference in this paper. Moreover, the phase sensitivity and response time of this phase detector are investigated. This phase detector is fabricated based on GaAs MMIC (monolithic microwave integrated circuit) technique. Experiment results indicate that the measured results of phase detection are in good agreement with the calculated results. The phase sensitivity can reach to 14μV/°@10GHz and the response time is about 356μs.
  • Keywords
    "Detectors","Microwave circuits","Microwave measurement","Microwave amplifiers","Microwave communication"
  • Publisher
    ieee
  • Conference_Titel
    SENSORS, 2015 IEEE
  • Type

    conf

  • DOI
    10.1109/ICSENS.2015.7370328
  • Filename
    7370328