• DocumentCode
    3721920
  • Title

    Sensing fresh water contamination using fluorescence methods

  • Author

    Julius Okache;Barry Haggett;Robin Maytum;Andrew Mead;David Rawson;Tahmina Ajmal

  • Author_Institution
    Department of Computer Science and Technology, University of Bedfordshire, Luton, United Kingdom LU1 3JU
  • fYear
    2015
  • Firstpage
    1
  • Lastpage
    4
  • Abstract
    Water quality monitoring requires characterization of a range of organic and inorganic components present within the sample. We present here initial findings in the design of a novel system to detect contaminants by characterizing their characteristic fluorescence fingerprints in a 3-dimensional excitation emission matrix. This is a proof of principle for a system that would then use principal component analysis to diagnose the individual contaminants present in real world samples. A high-resolution fluorescence spectrometer was used to characterize components and potential pollutants in water samples along with samples taken at two different times from the feed into a lake. Several types of fluorescent signals were observed including the commonly used UV `protein-like´ fluorescence as well as humic-like or yellow substances fluorescence. Development of this method will lead to a technique that will allow rapid identification of possible contaminants in water samples.
  • Keywords
    "Fluorescence","Water pollution","Lakes","Pollution measurement","Monitoring","Optical variables measurement","Spectroscopy"
  • Publisher
    ieee
  • Conference_Titel
    SENSORS, 2015 IEEE
  • Type

    conf

  • DOI
    10.1109/ICSENS.2015.7370462
  • Filename
    7370462