DocumentCode
3724295
Title
DC-Side Harmonic Mitigation in Single-Phase Bridge Inverter
Author
Junchaojie Tang;Haoran Wang;Xiaobi Fu;Siyuan Ma;Guorong Zhu
Author_Institution
Sch. of Autom., Wuhan Univ. of Technol., Wuhan, China
fYear
2015
Firstpage
251
Lastpage
254
Abstract
Because of the instantaneous imbalance of the ideal input power and output power, the DC-side of the general inverters will be disturbed by the reactive power and the pulsation power of twice-frequency at the AC-side. This fact will be harmful for the security, stability and reliability of the system. This paper presents a power-decoupling module which is able to compensate for the twice pulsation power and the reactive power at the AC-side by controlling the voltage of the two series capacitors in the power-decoupling module. Consequently, the harmonic currents of the DC-side current will be eliminated. The disturbance of the DC source from the inverter will be reduced. The stability and the reliability of the system will be improved. This paper establishes the simulation model of the H-bridge inverter based on the power-decoupling module. The correctness and the feasibility of the proposed harmonic power decoupling technique based on the power-decoupling module have been verified through comparison and analysis.
Keywords
"Harmonic analysis","Capacitors","Inverters","Power harmonic filters","Voltage control","Capacitance"
Publisher
ieee
Conference_Titel
Industrial Informatics - Computing Technology, Intelligent Technology, Industrial Information Integration (ICIICII), 2015 International Conference on
Type
conf
DOI
10.1109/ICIICII.2015.144
Filename
7373832
Link To Document