DocumentCode :
3726550
Title :
Electric Water Heater Energy Consumption Determination Using Outlet Temperature and Volumetric Estimation
Author :
P.J.C. Nel;M.J. Booysen;B. van der Merwe
Author_Institution :
Dept. of Electr. &
fYear :
2015
Firstpage :
665
Lastpage :
672
Abstract :
This paper presents the use of outlet temperature and water meter data as inputs to a physical model of a domestic electric water heater (EWH) for estimating the energy consumption for various control settings. Four sets of actual household data, consisting of at least 7 consecutive days each, is used to determine the accuracy of the energy consumption estimates in comparison to measured energy consumption. Both the outlet temperature and water meter data inputs used were able to estimate the total energy input with an error of less than 10 percent for 3 of the 4 datasets considered. Additionally, both methods are also implemented as a smartphone application that can be used to obtain input from users, as well as provide instantaneous feedback on the impact of control changes.
Keywords :
"Water heating","Temperature measurement","Energy consumption","Temperature sensors","Resistance heating","Temperature distribution"
Publisher :
ieee
Conference_Titel :
Computational Intelligence, 2015 IEEE Symposium Series on
Print_ISBN :
978-1-4799-7560-0
Type :
conf
DOI :
10.1109/SSCI.2015.102
Filename :
7376676
Link To Document :
بازگشت