DocumentCode :
3727378
Title :
Broadband measurement system for the specific absorption rate above 300 MHz
Author :
Ryo Shimofusa;Yoshinobu Okano
Author_Institution :
INFORMATIONENGINEERING, TOKYO CITY UNIVERSITY GRADUATE DIVISION, 1-18-1, Tamazutsumi, Setagaya-Ku, Tokyo, Japan 158-8557
fYear :
2015
Firstpage :
88
Lastpage :
90
Abstract :
The specific absorption rate (SAR) is an indicator of the thermal effects caused by microwave exposure in biological tissues. Electric field probe scanning has been used as a practical SAR evaluation technology until now. A measurement standard is necessary for any physical quantity. In general, the existence of a standard constructed with a physically different procedure is important in uncertainty evaluation of the measurement standard. In this report, a thermal SAR measurement method using an optical fiber thermal sensor is proposed. The thermal SAR measurement method is not suitable for dosimetric assessments for an actual cellular phone. Nevertheless, a thermal sensor works independently of the frequency, and is therefore suitable for primary testing of an electric field probe scanning system. The results show that the proposed method is able to measure SAR within an error range of 1-13% in frequency range of 300-800 MHz and 2-6 GHz.
Keywords :
"Temperature measurement","Phantoms","Antenna measurements","Thermal sensors","Microwave measurement","Specific absorption rate","Electric fields"
Publisher :
ieee
Conference_Titel :
Radio-Frequency Integration Technology (RFIT), 2015 IEEE International Symposium on
Type :
conf
DOI :
10.1109/RFIT.2015.7377896
Filename :
7377896
Link To Document :