DocumentCode
3732440
Title
Optimal design of compact main insulation structure of PETT
Author
Fangcheng L?;Danrong Li;Yunxiang Guo;Chao Fu;Hui Wang
Author_Institution
State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power, University Beijing, China
fYear
2015
Firstpage
303
Lastpage
306
Abstract
Compact main insulation structure of a power electronic traction transformer(PETT) is designed in this paper. Angle ring and electrostatic ring are set on the end of the high voltage winding to reduce the maximum electric field intensity value and improve the electric field distribution. A model of the end insulation structure is established in ANSYS. By the scanning method, the distance between the electrostatic ring and iron yoke is reduced to 13mm, and the optimal values of the end insulation structure are found.