DocumentCode
3732609
Title
Stator winding inter-turn short circuit faults severity detection controlled by OW-SVPWM without CMV of five-phase FTFSCW-IPM
Author
Ying Fan;Weixia Zhu;Xiangyang Zhang;Li Zhang
Author_Institution
College of Electrical Engineering, Southeast University, China
fYear
2015
Firstpage
1192
Lastpage
1197
Abstract
This paper presents a method aiming to detect different inter-turn short circuit fault severity by analyzing zero-sequence voltage for a new five-phase fault-tolerant fractional-slot concentrated winding interior permanent magnet motor (FTFSCW-IPM). To eliminate the effect of common mode voltage (CMV) in single DC power supply application, fault severity analysis is conducted based on an open-end winding (OW) space vector. This new method is verified by simulation results in a five-phase FTFSCW-IPM OW system.
Keywords
"Decision support systems","Circuit faults","Windings","Permanent magnet motors","Integrated circuit modeling","Silicon"