• DocumentCode
    3732609
  • Title

    Stator winding inter-turn short circuit faults severity detection controlled by OW-SVPWM without CMV of five-phase FTFSCW-IPM

  • Author

    Ying Fan;Weixia Zhu;Xiangyang Zhang;Li Zhang

  • Author_Institution
    College of Electrical Engineering, Southeast University, China
  • fYear
    2015
  • Firstpage
    1192
  • Lastpage
    1197
  • Abstract
    This paper presents a method aiming to detect different inter-turn short circuit fault severity by analyzing zero-sequence voltage for a new five-phase fault-tolerant fractional-slot concentrated winding interior permanent magnet motor (FTFSCW-IPM). To eliminate the effect of common mode voltage (CMV) in single DC power supply application, fault severity analysis is conducted based on an open-end winding (OW) space vector. This new method is verified by simulation results in a five-phase FTFSCW-IPM OW system.
  • Keywords
    "Decision support systems","Circuit faults","Windings","Permanent magnet motors","Integrated circuit modeling","Silicon"
  • Publisher
    ieee
  • Conference_Titel
    Electrical Machines and Systems (ICEMS), 2015 18th International Conference on
  • Type

    conf

  • DOI
    10.1109/ICEMS.2015.7385220
  • Filename