DocumentCode
3732695
Title
Reduction of common-mode current in parallel connected PV-inverters with negative grounding
Author
Liang Zhou;Lan Wang;Zhenxing Wu;Guangsen Wang;Meina Wu
Author_Institution
National Key Laboratory for Vessel Integrated Power System Technology, Naval University of Engineering, Wuhan, China
fYear
2015
Firstpage
1660
Lastpage
1665
Abstract
This paper is focused on the analysis and reduction of the common-mode current for parallel inverters with negative grounding in the photovoltaic (PV) generation system. Due to the existence of the solar parasitic capacitance to ground, transparent conductive oxide (TCO) corrosion occurs in some type of thin-film solar modules. The negative terminal of the thin-film array can be directly connected to the ground in a single PV-inverter to avoid TCO corrosion. However, a large common-mode current is injected when the negative terminals of parallel inverters connect to the ground directly. The performance of the proposed control strategy is verified by a PV system. The experimental results show that the performance of the proposed control strategy is as expected.
Keywords
"Grounding","Inverters","Corrosion","Time-frequency analysis","Photovoltaic systems","Parasitic capacitance"
Publisher
ieee
Conference_Titel
Electrical Machines and Systems (ICEMS), 2015 18th International Conference on
Type
conf
DOI
10.1109/ICEMS.2015.7385307
Filename
7385307
Link To Document