DocumentCode :
3732700
Title :
An arc fault detection system for the household photovoltaic inverter according to the DC bus currents
Author :
Kun Xia;Zihui He;Yin Yuan;Yiming Wang;Po Xu
Author_Institution :
School of Optical-Electrical and Computer Engineering, University of Shanghai for Science and Technology, Shanghai, China
fYear :
2015
Firstpage :
1687
Lastpage :
1690
Abstract :
An arc fault detection system for household photovoltaic inverter according to the DC bus currents was discussed in the paper. A current transformer was employed to capture currents of the DC bus. The detected signals were filtered by a band-pass filter to derive the meaningful waves. TMS320F28062 DSP was selected as the master chip. It accomplished the fast Fourier transform in chip and gave the pattern recognition for the frequency spectrum of the arc. It will disconnect the inverter from the DC bus when an arc fault is diagnosed. The proposed system has been successfully applied to detect the arc fault of the household photovoltaic inverter reliably.
Keywords :
"Inverters","Photovoltaic systems","Band-pass filters","Fault detection","Decision support systems","Current transformers"
Publisher :
ieee
Conference_Titel :
Electrical Machines and Systems (ICEMS), 2015 18th International Conference on
Type :
conf
DOI :
10.1109/ICEMS.2015.7385312
Filename :
7385312
Link To Document :
بازگشت