Impacts of industrial baseline errors in demand side management enabled enterprise control
Author :
Bo Jiang;Amro M. Farid;Aramazd Muzhikyan;Kamal Youcef-Toumi
Author_Institution :
Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
fYear :
2015
Firstpage :
3467
Lastpage :
3472
Abstract :
Despite the recognized importance of demand side management (DSM) for mitigating the impact of variable energy resources and reducing the system costs, the academic and industrial literature have taken divergent approaches to DSM implementation. The prequel to this work has demonstrated that the inflation of the net load baseline forecast, used by the industrial unit commitment formulation, leads to higher and costlier day-ahead scheduling of dispatchable resources compared to the academic method. Consequently, these baseline inflation errors have to be corrected in the downstream enterprise control activities at faster time scales, increasing the control efforts and reserve requirements for the real-time market dispatch and regulation service. This paper compares the two DSM approaches and quantifies the technical impact of industrial baseline errors in subsequent layers of control using an enterprise control methodology. The adopted enterprise control simulator encompasses three interconnected layers: a resource scheduling layer composed of a security-constrained unit commitment (SCUC), a balancing layer composed of a security-constrained economic dispatch (SCED), and a regulation layer. Baseline error is absent in the social welfare model. The simulations with the industrial model are run for different baseline error levels. The baseline inflation is assumed to have the same effects in the day-ahead and real-time market. The resulting implications of baseline errors on power grid imbalances and regulating reserve requirements are tracked. It is concluded that with the same regulating service, the introduction of baseline error leads to additional system imbalance compared to the social welfare model results, and the imbalance amplifies itself as the baseline error increases. As a result, more regulating reserves are required to achieve the same satisfactory system performance with higher baseline error.
Keywords :
"Generators","Load modeling","Real-time systems","Load forecasting","Mathematical model","Optimization","Job shop scheduling"
Publisher :
ieee
Conference_Titel :
Industrial Electronics Society, IECON 2015 - 41st Annual Conference of the IEEE
Type :
conf
DOI :
10.1109/IECON.2015.7392637
Filename :
7392637
Link To Document :
بازگشت