• DocumentCode
    3738411
  • Title

    An improved readout topology of resistive sensor array for reduced measurement error

  • Author

    Dayang Nurul Nahar Talib;Suhaidi Shafie;Mohd Nizar Hamidon;Fauzan Ahmad

  • Author_Institution
    Department of Electrical and Electronic Engineering, Faculty of Engineering, Universiti Putra Malaysia, Selangor, Malaysia
  • fYear
    2015
  • Firstpage
    96
  • Lastpage
    99
  • Abstract
    Readout circuit integrated with large scale sensors array is important for improving the effectiveness of data acquisition system. However to design such system, it will require a variety of additional components which contributes to the increment of power consumption. In this paper we proposed an improved method of readout topology for resistive sensor array to reduce the measurement error. A new equation is also proposed to obtain the resistance value. A simulation has been done on 8×8 matrix sensor array represented by 64 fixed resistors and 8 standard reference resistors. The results show that the optimum reference resistance is 510 Ω for the value range between 100 Ω and 100 kΩ, and the improved percentage error is kept to be lower than 5%.
  • Keywords
    "Standards","Microcontrollers","Multiplexing","RNA","Topology","Actuators"
  • Publisher
    ieee
  • Conference_Titel
    Circuits and Systems Symposium (ICSyS), 2015 IEEE International
  • Type

    conf

  • DOI
    10.1109/CircuitsAndSystems.2015.7394072
  • Filename
    7394072