DocumentCode
3738411
Title
An improved readout topology of resistive sensor array for reduced measurement error
Author
Dayang Nurul Nahar Talib;Suhaidi Shafie;Mohd Nizar Hamidon;Fauzan Ahmad
Author_Institution
Department of Electrical and Electronic Engineering, Faculty of Engineering, Universiti Putra Malaysia, Selangor, Malaysia
fYear
2015
Firstpage
96
Lastpage
99
Abstract
Readout circuit integrated with large scale sensors array is important for improving the effectiveness of data acquisition system. However to design such system, it will require a variety of additional components which contributes to the increment of power consumption. In this paper we proposed an improved method of readout topology for resistive sensor array to reduce the measurement error. A new equation is also proposed to obtain the resistance value. A simulation has been done on 8×8 matrix sensor array represented by 64 fixed resistors and 8 standard reference resistors. The results show that the optimum reference resistance is 510 Ω for the value range between 100 Ω and 100 kΩ, and the improved percentage error is kept to be lower than 5%.
Keywords
"Standards","Microcontrollers","Multiplexing","RNA","Topology","Actuators"
Publisher
ieee
Conference_Titel
Circuits and Systems Symposium (ICSyS), 2015 IEEE International
Type
conf
DOI
10.1109/CircuitsAndSystems.2015.7394072
Filename
7394072