Title :
Measurement system for wearable devices of intra-body communication using electro-optic technique
Author :
Daiki Ayuzawa;Yasuaki Takizawa;Sayaka Sugo;Kazuki Matsumoto;Mitsuru Shinagawa
Author_Institution :
Faculty of Science and Engineering, Hosei University, 3-7-2, Kajino-cho, Koganei-shi, Tokyo, Japan
Abstract :
This paper describes a measurement system for a wearable device of intra-body communication, in which the human body is used as a transmission medium. An instrument driven by AC power overestimates a voltage signal around the human body received by the wearable device, preventing precise measurements from being performed. We developed a new measurement system using an electro-optic technique to enable precise measurements. The wearable device is electrically isolated from the instrument. The measurement system has a bandwidth from 10 kHz to 20 MHz and a 40-dB signal-to-noise ratio at a wearable transmitter output voltage of 0.36 V.
Keywords :
"Optical transmitters","Yttrium","Voltage measurement","Receivers","Electric fields","Electrodes","Signal generators"
Conference_Titel :
Consumer Electronics (GCCE), 2015 IEEE 4th Global Conference on
DOI :
10.1109/GCCE.2015.7398576