DocumentCode
3741170
Title
Design of electrode geometry for co-planar CdZnTe radiation detectors
Author
Yuelu Zhang;Linjun Wang;Jianming Lai;Jian Huang;Jijun Zhang;Run Xu;Yun Shen
Author_Institution
School of Materials Science and Engineering, Shanghai University Shanghai 200444, PR China
fYear
2015
fDate
7/1/2015 12:00:00 AM
Firstpage
474
Lastpage
477
Abstract
The photoelectric property of co-planar Au/CdZnTe radiation detectors has been simulated by Silvaco TCAD tools. The electrode geometry including the electrode width and spacing are studied by their effects on quantum efficiency and transient response. The best electrode spacing for co-planar Au/CdZnTe detectors is 0.1 mm for 0.1mm electrode width, and 0.5 mm for 1mm electrode width.
Keywords
"Electrodes","Detectors","Electric fields","Transient response","Yttrium","Radiation detectors","Electric potential"