• DocumentCode
    3745581
  • Title

    Design and Analysis of Static Pressure Distribution and Measurement on Contact Interface

  • Author

    Zhuo-Fu Liu;Guang-Sheng Xi;Lin Wang;Zhongming Luo;Yongbo Li

  • Author_Institution
    Higher Educ. Key Lab. for Meas. &
  • fYear
    2015
  • Firstpage
    1050
  • Lastpage
    1054
  • Abstract
    The developed human body-seat surface pressure measurement system is rational and feasible, and can measure the human body and the pressure distribution dynamically and in real time. The human body seat surface pressure distribution measurement system mainly includes FSR pressure sensor array and STC15F2K60S2 microcontroller. First, the standard weight scale is used to calibrate the FSR sensor and draw the output voltage curve under different pressure inputs. STC15F2K60S2 microcontroller has eight 10-bits AD converters. System adopts RS232 serial interface with the PC for serial communication. The MATLB is employed to conduct data processing and analysis, while the band pass filter is applied for noise suppression. After filtering data in the pre-processing stage, Fourier transform is used to analyze the valid data, then use SP Tool tools for simulation.
  • Keywords
    "Pressure measurement","Band-pass filters","Pressure sensors","Analog-digital conversion","Digital filters","IIR filters","Surface treatment"
  • Publisher
    ieee
  • Conference_Titel
    Instrumentation and Measurement, Computer, Communication and Control (IMCCC), 2015 Fifth International Conference on
  • Type

    conf

  • DOI
    10.1109/IMCCC.2015.227
  • Filename
    7406006