Title :
Assessment of fluid drag loss in a flooded rotor electro-hydrostatic actuator motor
Author :
P S Sangha;T Sawata;J Yon;P H Mellor
Author_Institution :
UTC Aerospace Systems, Motor Drive Systems Centre, Huskisson Way, Solihull, B90 4SS
fDate :
5/1/2015 12:00:00 AM
Abstract :
For a permanent magnet (PM) motor used in an electro-hydrostatic actuation system, fluid drag loss in the air gap can be as high as 60% of motor internal losses and affects the motor efficiency; especially at low temperatures where the viscosity of the hydraulic fluid increases significantly. A PM motor has been designed and built to assess electromagnetic, fluid drag loss and dynamic performance. The design process utilised a theoretical equation for the fluid drag loss estimation which assumes a laminar flow. Assumption of the laminar flow has been validated by computational fluid dynamic analysis. A dummy motor was built and the fluid drag losses were measured for various speeds and temperatures. The test results show reasonable agreement with the theoretical calculation although the self-heating effect of the fluid made measurements at constant temperatures difficult.
Keywords :
"Rotors","Drag","Temperature measurement","Brushless motors","Loss measurement","Torque"
Conference_Titel :
Electric Machines & Drives Conference (IEMDC), 2015 IEEE International
DOI :
10.1109/IEMDC.2015.7409050