DocumentCode :
3747632
Title :
Analysis of stable operating condition of q-axis current feedback control system of IPMSM in flux weakening region
Author :
Soichiro Kurita;Keiichiro Kondo
Author_Institution :
Graduate School and Faculty of Engineering Chiba University, 1-33, Yayoi-cho, Inage-ku, Chiba-shi, Chiba, Japan
fYear :
2015
fDate :
5/1/2015 12:00:00 AM
Firstpage :
860
Lastpage :
865
Abstract :
A torque control method for permanent magnet synchronous motor (PMSM) in flux weakening region has been proposed. However in particular case, current control response of proposed method becomes oscillatory. Therefore, stable operating condition is analyzed in this paper. It is revealed that the gain of transfer function from feedback component of voltage phase angle to actual q-axis current is increased in the high frequency region close to the resonant frequency. It is revealed that the ratio of d-axis and q-axis stator windings linkage flux should be considered for the stable operation because it affects the q-axis current control performance. The revealed stable operating condition is verified by experimental test with 1kW class IPMSM.
Keywords :
"Resonant frequency","Voltage control","Inverters","Transfer functions","Torque","Permanent magnet motors","Current control"