DocumentCode :
3747783
Title :
Evaluation of the additional loss due to supply voltage distortion in relation to induction motor efficiency rating
Author :
Colin Debruyne;Bram Corne;Peter Sergeant;Jan Desmet;Lieven Vandevelde
Author_Institution :
Electrical Energy Laboratory (EELAB) Department of Electrical Energy, Systems and Automation (EESA) Ghent University, Sint-Pietersnieuwstraat 41, B-9000 Ghent, Belgium
fYear :
2015
fDate :
5/1/2015 12:00:00 AM
Firstpage :
1881
Lastpage :
1887
Abstract :
Distortion of the supply voltage undoubtedly reduces the overall energy efficiency of induction motors. The goal of this paper is to evaluate additional harmonic losses in relation to the machine´s initial efficiency rating. However, due to the relatively small amount of additional loss, the main drawback when evaluating the effect of supply voltage distortion on the machines´ overall efficiency is the measurement accuracy of the current methods. In order to validate the effect of motor efficiency rating in relation to supply voltage distortion, the use of the parameter "harmonic active power" is suggested. This new strategy is subsequently validated by measurements and compared to current methods such as the NEMA MG1, or the procedure according to the IEC60034-2-3. Although this strategy is only valid under certain constraints, this new method enables a fast and highly accurate measurement of the additional loss. Consequently, this parameter is used to validate the effect of efficiency rating of induction motors in relation to the additional loss related supply voltage distortion.
Keywords :
"Loss measurement","Harmonic analysis","Distortion measurement","Power system harmonics","Voltage measurement","Harmonic distortion"
Publisher :
ieee
Conference_Titel :
Electric Machines & Drives Conference (IEMDC), 2015 IEEE International
Type :
conf
DOI :
10.1109/IEMDC.2015.7409321
Filename :
7409321
Link To Document :
بازگشت