    SPECT collimator dependency of scatter and validation of transmission dependent scatter compensation methodologies

  • Author

    Kim, K.M. ; Watabe, H. ; Shidahara, M. ; Iida, H.

  • Author_Institution
    Dept. of Investigative Radiol., Nat. Cardiovascular Center Res. Inst., Suita, Japan
  • Volume
    2
  • fYear
    2000
  • fDate
    2000
  • Abstract
    Scatter correction is important for absolute quantification in SPECT. Among the approaches taken to achieve scatter correction, some methods using transmission information for scatter estimation requires the scatter models based on the physical characteristics of the scattered photons. The influence of the SPECT collimator on the characteristics of the scattered photon, however, has not been well studied yet. In this study, we investigated the relationship between scatter and collimator design for the use of the transmission-dependent convolution subtraction (TDCS) method. Monte-Carlo simulations with various collimator acceptance angles and experiments with 4 collimators of 2 SPECT cameras were performed to obtain the scatter fraction (SF) and the line-spread function (LSF) of Tc99 m. The experiments with I-123 also used 6 collimators of 3 SPECT systems to obtain the SF and the LSF. In the simulations, the SF of Tc-99 m did not change with the collimator acceptance angles. The LSFs measured for Tc-99 m showed an excellent agreement between collimators. In the experiments for I-123, the SF was practically the same for the 6 collimators, although a small difference could be observed, due to the septal penetration. Also, the shape of the LSF was very similar between the collimators. These results reveal that scatter is independent of SPECT collimator design for Tc-99 m and even I-123, and that the TDCS could be applicable to scatter correction of I-123 using a unique collimator-independent set of parameters
  • Keywords
    Monte Carlo methods; biomedical equipment; compensation; convolution; gamma-ray scattering; image reconstruction; medical image processing; single photon emission computed tomography; Monte-Carlo simulation; SPECT collimator dependence; absolute quantification; collimator acceptance angles; collimator design; convolution subtraction; line-spread function; scatter correction; scatter models; transmission dependent scatter compensation; Cameras; Cardiology; Convolution; Electromagnetic scattering; Optical collimators; Particle scattering; Radioactive materials; Radiology; Scattering parameters; Single photon emission computed tomography;
  • fLanguage
    English