DocumentCode
374851
Title
TTR algorithm for the inversion of the exponential X-ray transform [SPECT application]
Author
Wagner, J.-M. ; Noo, E.
Author_Institution
Liege Univ., Belgium
Volume
2
fYear
2000
fDate
2000
Abstract
Presents an FBP algorithm suitable for image reconstruction from exponential X-ray projections sampled on any subset of the sphere that includes great circles. This algorithm is similar to the TTR-algorithm of Ra et al. (1982) for non-attenuated projections. It is derived by combining all reconstructions that can be obtained from the subsets of measurements corresponding to a great circle. The authors´ results generalize those published by I. Hazou (1988) and Weng et al. (1996) for reconstruction from projections sampled on the unit sphere. However, they remain modest as they only apply to specific sets of measurements
Keywords
image reconstruction; medical image processing; single photon emission computed tomography; transforms; SPECT; TTR algorithm; exponential X-ray transform; great circles; measurement subsets; medical diagnostic imaging; nuclear medicine; Attenuation; Biomedical applications of radiation; Collimators; Geometry; Image reconstruction; Intensity modulation; Optical imaging; Reconstruction algorithms; Three dimensional displays; X-ray imaging;
fLanguage
English
Publisher
ieee
Conference_Titel
Nuclear Science Symposium Conference Record, 2000 IEEE
Conference_Location
Lyon
ISSN
1082-3654
Print_ISBN
0-7803-6503-8
Type
conf
DOI
10.1109/NSSMIC.2000.950095
Filename
950095
Link To Document