• DocumentCode
    3748978
  • Title

    Electrocardiographic detection and monitoring of pulmonary Hypertension

  • Author

    Marjolein C de Jongh;Vivian P Kamphuis;Sumche Man;Arie C Maan;Hubert W Vliegen;Cees A Swenne

  • Author_Institution
    Leiden University Medical Center, The Netherlands
  • fYear
    2015
  • Firstpage
    541
  • Lastpage
    544
  • Abstract
    Initial symptoms of pulmonary hypertension (PH) are easily missed, while early diagnosis and treatment is essential. Pulmonary arterial pressure (PAP) assessment by right heart catheterization or echocardiography is not feasible for periodic monitoring of patients at risk of developing PH. Here we investigate the possible use of the electrocardiogram (ECG) as a screening instrument for early PH detection and for monitoring its course. We studied patients in whom at two diferent dates mean PAP measurements were done (either by echocardiography or by right heart catheterization) and in whom two 12-lead ECGs had been made within three months from the dates on which the mean PAP assessments were done. In each of these patients, the change in mean PAP was classified into one of three categories: decrease> 7.5 mmHg, increase> 7.5 mmHg, or limited change (increase/decrease ≤ 7.5 mmHg). The ECG output variable was a projection of the ventricular gradient (VG) optimized for right ventricular pressure overload detection: VGrvpo, A total of 39 patients (15/24 m alelJem ale, age 60±12 years) was studied. Mean PAP and VGrvpo changed by -15±7 mmHg and -13±26 mV·ms in the mean PAP decrease group, and by 12±4 mmHg and 8±12 m V·ms in the mean PAP increase group, respectively. The VGrvpo changes in the mean PAP increase and decrease groups difered significantly (P<;0. 05). A total of 39 patients (15/24 m alelJem ale, age 60±12 years) was studied. Mean PAP and VGrvpo changed by -15±7 mmHg and -13±26 mV·ms in the mean PAP decrease group, and by 12±4 mmHg and 8±12 mV·ms in the mean PAP increase group, respectively. The VGrvpo changes in the mean PAP increase and decrease groups differed significantly (P<;0. 05). These results suggest that the ECG can be used as a monitoring instrument to detect changes in PAP.
  • Keywords
    "Electrocardiography","Heart","Catheterization","Monitoring","Mercury (metals)","Biomedical monitoring","Current measurement"
  • Publisher
    ieee
  • Conference_Titel
    Computing in Cardiology Conference (CinC), 2015
  • ISSN
    2325-8861
  • Print_ISBN
    978-1-5090-0685-4
  • Electronic_ISBN
    2325-887X
  • Type

    conf

  • DOI
    10.1109/CIC.2015.7410967
  • Filename
    7410967