Title :
The impact of transmission line terminations on radiated emissions
Author :
Wong, Bert ; Fynn, K. ; Schlagenhaufer, F. ; Cantoni, A.
Author_Institution :
Curtin Univ. of Technol., Perth, WA, Australia
Abstract :
Terminating transmission lines at either the source or the load side with a damping resistor is often used to improve the signal integrity of clock or control lines on PCBs. While a number of termination variants may produce similar results in respect to signal integrity the EMC performance can differ due to a different current and voltage distribution along the line. This paper investigates the impact of transmission line terminations on radiated emissions
Keywords :
electromagnetic compatibility; electromagnetic interference; transmission line theory; EMC performance; PCBs; back matching; clock; control lines; current distribution; damping resistor; forward matching; load side; polar plot; radiated emissions; signal integrity improvement; source side; transmission line terminations impact; voltage distribution; Australia; Clocks; Damping; Electromagnetic compatibility; Electromagnetic radiation; Frequency; Impedance; Transmission line matrix methods; Transmission lines; Voltage;
Conference_Titel :
Electromagnetic Compatibility, 2001. EMC. 2001 IEEE International Symposium on
Conference_Location :
Montreal, Que.
Print_ISBN :
0-7803-6569-0
DOI :
10.1109/ISEMC.2001.950529