• DocumentCode
    374941
  • Title

    A time-domain method for measuring the minimum shielding effectiveness of coaxial cable assemblies

  • Author

    Kudyan, Hirayr M.

  • Author_Institution
    Lucent Technol. Bell Labs., Whippany, NJ, USA
  • Volume
    1
  • fYear
    2001
  • fDate
    2001
  • Firstpage
    63
  • Abstract
    This paper reports a time domain pulse technique for measuring the minimum shielding effectiveness of coaxial cable assemblies. Experimental data for coaxial cable assemblies are presented and compared. The paper also presents a simplified circuit model to simulate the experiment, which confirms the validity of the measurement scheme. At high frequencies, this method of measuring shielding effectiveness is demonstrated to be a more reliable and time-effective alternative to well-known frequency domain techniques
  • Keywords
    cable shielding; coaxial cables; electromagnetic compatibility; electromagnetic interference; electromagnetic shielding; time-domain analysis; 0.4 ns; 400 V; 50 ns; EMC performance; EMI emission compliance; coaxial cable assemblies; minimum shielding effectiveness measurement; simplified circuit model; time domain pulse technique; wireless communications systems; Assembly; Cable shielding; Coaxial cables; Conductors; Frequency domain analysis; Frequency measurement; Pulse measurements; Sampling methods; Time domain analysis; Time measurement;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electromagnetic Compatibility, 2001. EMC. 2001 IEEE International Symposium on
  • Conference_Location
    Montreal, Que.
  • Print_ISBN
    0-7803-6569-0
  • Type

    conf

  • DOI
    10.1109/ISEMC.2001.950534
  • Filename
    950534