  • Title

    Gait analysis using a single depth camera

  • Author

    Minxiang Ye;Cheng Yang;Vladimir Stankovic;Lina Stankovic;Andrew Kerr

  • Author_Institution
    Department of Electronic and Electrical Engineering, University of Strathclyde, Glasgow, G1 1XW, UK
  • fYear
    2015
  • Firstpage
    285
  • Lastpage
    289
  • Abstract
    Gait analysis is often used as part of the rehabilitation program for post-stoke recovery assessment. Since current optical diagnostic and patient assessment tools tend to be expensive and not portable, this paper proposes a novel marker-based tracking system using a single depth camera which provides a cost-effective solution suitable for home and clinic use. The proposed system can simultaneously generate motion patterns even within a complex background using the proposed geometric model-based algorithm and autonomously provide gait analysis results. The processed rehabilitation data can be accessed by cross-platform mobile devices using cloud-based services enabling emerging tele-rehabilitation practices. Experimental validation shows a good agreement with state-of-the-art non-portable and expensive industrial standards.
  • Keywords
    "Cameras","Signal processing algorithms","Three-dimensional displays","Mobile communication","Multimedia communication","Knee","Trajectory"