DocumentCode
375802
Title
Underwater lidar imaging (UWLI) in 3 m tank with highly turbid waters
Author
Duo-Min He ; Seet, G.G.L.
Author_Institution
Robotics Res. Center, Nanyang Technol. Univ., Singapore, Singapore
Volume
1
fYear
2001
fDate
15-19 July 2001
Abstract
Based on our newly-designed series of targets at intervals, the range-gated phenomenon of underwater lidar imaging is much clarified. In extremely turbid water with attenuation 2.3/m, targets 1.5 m apart in distance cannot be observed by the non-gated camera at all, but its image could be recorded by our UWLI system.
Keywords
CCD image sensors; image intensifiers; laser ranging; optical radar; turbidity; 1.5 m; backscattering; bar test targets; extremely turbid water; intensified CCD; range-gated phenomenon; relative delay time; targets at intervals; underwater lidar imaging; Attenuation; Cameras; Delay effects; Helium; Laboratories; Laser radar; Light scattering; Optical attenuators; Optical imaging; Robots;
fLanguage
English
Publisher
ieee
Conference_Titel
Lasers and Electro-Optics, 2001. CLEO/Pacific Rim 2001. The 4th Pacific Rim Conference on
Conference_Location
Chiba, Japan
Print_ISBN
0-7803-6738-3
Type
conf
DOI
10.1109/CLEOPR.2001.967784
Filename
967784
Link To Document