DocumentCode
3758186
Title
Calculation of no-load saturation curve for wound field synchronous machines based on magnetic equivalent circuits and conformal mapping
Author
Ana Hanic;Zlatko Hanic;Mario Vrazic;Damir Zarko
Author_Institution
University of Zagreb, Faculty of Mining, Geology and Petroleum Engineering, Croatia
fYear
2015
Firstpage
513
Lastpage
518
Abstract
This paper describes a method for calculation of the no-load saturation curve for wound field synchronous machines based on magnetic equivalent circuits and conformal mapping. The method uses conformal mapping to calculate reluctances of the magnetically active parts of the machine which are then used in magnetic equivalent circuit for the calculation of magnetic fluxes. Proposed method is applied to a salient, six-pole, 400 V, 50 Hz synchronous machine with double layered armature winding and obtained results are compared with finite element method.
Keywords
"Saturation magnetization","Magnetic circuits","Electron tubes","Magnetic flux","Synchronous machines","Conformal mapping","Equivalent circuits"
Publisher
ieee
Conference_Titel
Electrical Machines & Power Electronics (ACEMP), 2015 Intl Conference on Optimization of Electrical & Electronic Equipment (OPTIM) & 2015 Intl Symposium on Advanced Electromechanical Motion Systems (ELECTROMOTION), 2015 Intl Aegean Conference on
Type
conf
DOI
10.1109/OPTIM.2015.7426979
Filename
7426979
Link To Document