DocumentCode :
3758620
Title :
Raw EEG signal processing for BCI control based on voluntary eye blinks
Author :
Michael Varela
Author_Institution :
Department of Computer Engineering, ITCR, Cartago, Costa Rica
fYear :
2015
Firstpage :
1
Lastpage :
6
Abstract :
This article shows a method for using the voluntary blinks as a control tool in a BCI (Brain Computer Interface), based on the raw EEG (Electroencephalography) signal generated by the NeuroSky Mindwave Mobile device, which use an Arduino with bluetooth module "BlueSMiRF-Silver" as a receiver. The processing of the raw EEG signal is based on the use of a median filter as preprocessing stage, and a mode filter of the signal output, with a large number of samples. With this method, a conditioned signal is generated and then using a simple algorithm that recognizes the corresponding pattern, the voluntary blinks are detected and the involuntary blinks are despised. The results show that accuracy obtained of the method is significant, approximately 90%.
Keywords :
"Electroencephalography","Filtering algorithms","Mobile communication","Visualization","Nickel","Detectors","Bluetooth"
Publisher :
ieee
Conference_Titel :
Central American and Panama Convention (CONCAPAN XXXV), 2015 IEEE Thirty Fifth
Type :
conf
DOI :
10.1109/CONCAPAN.2015.7428477
Filename :
7428477
Link To Document :