    Voltage and frequency regulation of a self-excited triple stator induction generator in a micro hydropower plant

  • Author

    O. A. Flores;U. E. Dur?n

  • Author_Institution
    Departamento de Ingenier?a El?ctrica, Universidad Nacional Aut?noma de Honduras, Tegucigalpa, D. C., Honduras
  • fYear
    2015
  • Firstpage
    1
  • Lastpage
    4
  • Abstract
    Asynchronous machines are a viable option for the use of the energy offer by little renewable potentials due to the advantages presented against its synchronous counterpart. With the implementation of a greater number of three phases, to these advantages add up improvements in performance that offers a multiphase structure. This paper proposed a static synchronous compensator (STATCOM) controlled by pulse width modulation by space vector (SVPWM), implemented to a self-excited triple stator induction generator for stabilizing the voltage and frequency to the variation of the load connected to its terminals. The application of the system in a micro hydropower plant is proposed.