• DocumentCode
    3763272
  • Title

    Influence of rail wear on output voltage of eddy-current rail displacement sensor

  • Author

    Yoshifumi Shimojima;Yinggang Bu;Tsutomu Mizuno;Takafumi Asahi;Makoto Ito;Shigemi Enoki

  • Author_Institution
    Faculty of Engineering, Shinshu University, Nagano, Japan
  • fYear
    2015
  • Firstpage
    396
  • Lastpage
    401
  • Abstract
    This paper describes the structure and output voltage characteristics of a rail displacement sensor comprising triangular coils. The calculation was demonstrated under a few assumptions. The maximum output voltage error between the measured and the calculated values was 2.4%. The influence of rail wear on output voltage leads to a displacement error of 12 mm.
  • Keywords
    "Rails","Coils","Impedance","Measurement uncertainty","Displacement measurement","Impedance measurement","Capacitance"
  • Publisher
    ieee
  • Conference_Titel
    Sensing Technology (ICST), 2015 9th International Conference on
  • Electronic_ISBN
    2156-8073
  • Type

    conf

  • DOI
    10.1109/ICSensT.2015.7438429
  • Filename
    7438429