DocumentCode
3763305
Title
Electrical Capacitance Tomography with a variable topology
Author
Stephan M?hlbacher-Karrer;Hubert Zangl
Author_Institution
Institute of Smart System Technologies, Sensors and Actuators, Alpen Adria Universit?t, Klagenfurt, 9020, Austria
fYear
2015
Firstpage
565
Lastpage
569
Abstract
In this paper we present a novel approach for Electrical Capacitance Tomography (ECT) with a variable electrode topology of the sensor front end. The topology of the ECT can be continuously varied while the reconstruction takes place. The unique combination of light weight signal processing chain with a variable dual plate planar sensor front end meets the usability and performance requirements of robotic and mobile applications. The experimental results show the feasibility of this approach achieving reconstruction results with low artefacts even with a low number of electrodes not only in the vicinity of the electrodes but also in the center of the Region of Interest (ROI). Moreover, this sensor topology can be miniaturized which eases the integration, e.g., on a robot´s end effector.
Keywords
"Electrodes","Sensors","Topology","Image reconstruction","Solid modeling","Permittivity","Current measurement"
Publisher
ieee
Conference_Titel
Sensing Technology (ICST), 2015 9th International Conference on
Electronic_ISBN
2156-8073
Type
conf
DOI
10.1109/ICSensT.2015.7438462