Title :
Modeling and flux leakage analysis for long-stator PM linear motor including longitudinal end effects
Author :
Ming Na Ma;Li Yi Li
Author_Institution :
School of Electrical Engineering and Automation, Hefei University of Technology, Hefei 230009, China
Abstract :
The main advantages of long-stator permanent magnet (PM) linear motor are light mover and fixed cables. But it has longitudinal end effects, which causes uneven airgap magnetic field distribution. The equivalent magnetic circuit model in long-stator linear motor differs from that in rotary and short-stator counterparts. The purpose of this paper is to establish accurate equivalent magnetic circuit model including longitudinal end effects for long-stator PM linear motor. The free parameter representing uneven flux conditions is introduced in the model. Further, flux leakage coefficients are calculated and compared by proposed model and electromagnetic fields analysis. Finally the revised mathematical expression of unload electromotive force (EMF) are presented and experiment validate the accuracy of analysis results.
Keywords :
"Magnetic circuits","Integrated circuit modeling","Analytical models","Magnetic flux leakage","Permanent magnet motors","Atmospheric modeling","Magnetic fields"
Conference_Titel :
Applied Superconductivity and Electromagnetic Devices (ASEMD), 2015 IEEE International Conference on
Print_ISBN :
978-1-4673-8106-2
DOI :
10.1109/ASEMD.2015.7453675