DocumentCode :
3768128
Title :
Research of the loss of the corrugated stainless steel pipe in HTS cable
Author :
Xi Ze Zhang;Xi Hua Zong;Yun Wu Han;Xiang Tian;Xiao Hong Lu;Zhi Guang Yu
Author_Institution :
Superconducting Project Technologies Research Centre, Shanghai Electric Cable Research Institute, Shanghai 200093, China
fYear :
2015
Firstpage :
576
Lastpage :
577
Abstract :
Stainless steel is usually non-magnetic or low magnetic austenitic stainless steel, which may convert to martensite when mechanical deformed. The stainless steel corrugated pipe becomes magnetic when marttensite exist, which cause hysteresis loss happens when AC current pass through the cable inside the corrugated pipe. In this paper, the hysteresis loss of the corrugated pipe was tested, and the metallographic and hysteresis loop of the steel was learned.
Keywords :
"Magnetic hysteresis","Superconducting cables","Steel","Power cables","High-temperature superconductors","Cable shielding","Cable insulation"
Publisher :
ieee
Conference_Titel :
Applied Superconductivity and Electromagnetic Devices (ASEMD), 2015 IEEE International Conference on
Print_ISBN :
978-1-4673-8106-2
Type :
conf
DOI :
10.1109/ASEMD.2015.7453711