• DocumentCode
    3770563
  • Title

    The measurement of dimensions of insulated magnet wire

  • Author

    Richard V. Carmer

  • Author_Institution
    United Technologies - Essex, 1510 Wall Street, Fort Wayne, IN 46804, United States
  • fYear
    1985
  • Firstpage
    39
  • Lastpage
    42
  • Abstract
    The precision and accuracy of a test method for measuring the dimensions of magnet wire depends upon the specific test method. There are enough discrepancies between the ASTM and IEC test methods to affect that precision and accuracy. There is a need to eliminate those discrepancies in the test methods so that there is uniformity worldwide.
  • Keywords
    "Wires","Films","Force measurement","Size measurement","Standards","Force","Correlation"
  • Publisher
    ieee
  • Conference_Titel
    Electrical/Electronics Insulation Conference, 1985 EIC 17th
  • Print_ISBN
    978-1-5090-3115-3
  • Type

    conf

  • DOI
    10.1109/EIC.1985.7458576
  • Filename