• DocumentCode
    3770587
  • Title

    A comparison of solvent versus solventless electrical insulating varnishes via systems testing

  • Author

    Mark Winkeler

  • Author_Institution
    The P. D. George Company, St. Louis, Missouri 63147, United States
  • fYear
    1985
  • Firstpage
    162
  • Lastpage
    166
  • Abstract
    As systems testing becomes more and more engrained in the electrical industry, studies involving single component changes in the design of a system become most important. Cases in which ground and phase insulations have been substituted have had a good deal of work done on them. These cases have been done to show the equivalence of substituted products versus standard products which were originally tested. This study involves the substitution of electrical insulating varnishes. The testing instituted the use of abbreviated sets of samples which were tested side by side.
  • Keywords
    "Testing","Aging","Wires","Solvents","Insulation","Magnetomechanical effects","Coils"
  • Publisher
    ieee
  • Conference_Titel
    Electrical/Electronics Insulation Conference, 1985 EIC 17th
  • Print_ISBN
    978-1-5090-3115-3
  • Type

    conf

  • DOI
    10.1109/EIC.1985.7458600
  • Filename
    7458600