DocumentCode
3770599
Title
Space factor of amorphous metal laminations
Author
K. C. Lin
Author_Institution
Westinghouse Electric Corporation, 469 Sharpsville Avenue, Sharon, Pennsylvania 16146, United States
fYear
1985
Firstpage
214
Lastpage
218
Abstract
Space factor is used to determine the compactness of a processed transformer core. It is desirable that the method used for determination of the space-factor represents that of the actual core. Several methods are available for determining space factor, including: the ASTM 719-75 lamination stack method, the wound toroid method, and the stacked core model method.
Keywords
"Lamination","Steel","Windings","Silicon","Clamps","Degradation"