DocumentCode :
3771033
Title :
Sealed tube test techniques for hermetic enamel evaluation
Author :
Robert S. Olsen
Author_Institution :
General Electric Company, Fort Wayne, Indiana, USA
fYear :
1971
Firstpage :
119
Lastpage :
122
Abstract :
The work carried out indicates that the level of moisture sealed into a tube directly affects the rate of formation of decomposition products, such as Refrigerant 22.It is a reasonable assumption that aluminum chloride is formed continuously on the wire. It is not until all the free water becomes chemically combined that anhydrous aluminum chloride can form and begin to catalyze the Refrigerant 22 formation.
Keywords :
"Electron tubes","Aging","Wires","Refrigerants","Moisture","Glass","Heating"
Publisher :
ieee
Conference_Titel :
Electrical Insulation Conference, 1971 EIC 10th
Print_ISBN :
978-1-5090-3116-0
Type :
conf
DOI :
10.1109/EIC.1971.7460788
Filename :
7460788
Link To Document :
بازگشت