DocumentCode :
3771527
Title :
Causes of insulation failure in medium size rotating electrical machinery: As viewed by a repair shop engineer
Author :
Samuel Heller
Author_Institution :
Consolidated Electric Motor Co., New York, N.Y.
fYear :
1963
Firstpage :
214
Lastpage :
215
Abstract :
When repairing rotating equipment in the repair shop, the problem is often not just replacing what was originally in the unit, but in many cases to determine whether some special environment or application caused the failure - and to correct it so that it will not happen again.
Keywords :
"Insulation","Windings","Maintenance engineering","Wires","AC motors","Testing","Coatings"