DocumentCode
3771583
Title
Tree-deterioration mechanism of water immersed polyethylene coated wire and its improvement of the insulation life
Author
Takao Miyashita;Toshio Inoue
Author_Institution
Hitachi Research Laboratory, Hitachi. Ltd., Hitachi-shi, Ibaraki-ken, Japan
fYear
1969
Firstpage
131
Lastpage
135
Abstract
In recent years, submersible pumping units have been winning greater recognition for their economy and their good performance properties. As a result, they have found wide use in the manufacturing industries. One insulating system of submersible motors is the type in which insulating wires are wound for the stator, and wires coated with polyethylene are often used as the insulating wires in this case.
Keywords
"Wires","Polyethylene","Electric breakdown","Breakdown voltage","Insulation","Electrodes","Conductors"
Publisher
ieee
Conference_Titel
Electrical Insulation Conference, 1969 9th