DocumentCode :
3771989
Title :
Spatial Stress Analysis on Anchorage Zone of Cable-Stayed Bridge Tower
Author :
Cui Nannan;Jia Buyu;Wang Yifan;Yu Xiaolin;Yan Quansheng
Author_Institution :
South China Univ. of Technol., Guangzhou, China
fYear :
2015
Firstpage :
730
Lastpage :
733
Abstract :
The anchorage zone of cable-stayed bridge tower is the key zone related to the safety of the bridge. Traditionally, prestress tendons are arranged in the concrete tower, in order to avoid the shortcoming of circumferential tendons, a new layout of prestress tendons named as "one-way prestress tendons" is put forward. This paper analyze the spatial stress state of this new design by the software ANSYS. Three load cases are considered: tensioning the prestress tendons only, loading the designed stay-cable force and the one stay-cable broken condition. The results show that: this new design can ensure the safety of the tower and will be reliable in practice.
Keywords :
"Stress","Tendons","Poles and towers","Force","Bridges","Power cables","Finite element analysis"
Publisher :
ieee
Conference_Titel :
Intelligent Systems Design and Engineering Applications (ISDEA), 2015 Sixth International Conference on
Type :
conf
DOI :
10.1109/ISDEA.2015.185
Filename :
7462722
Link To Document :
بازگشت