• DocumentCode
    3772445
  • Title

    Influence of dielectric stress concentration on voltage endurance of epoxy-mica generator insulation

  • Author

    A. Wichmann;P. Gruenewald

  • Author_Institution
    Kraftwerk Union AG, Muelheim/Ruhr, West Germany
  • fYear
    1976
  • fDate
    6/1/1976 12:00:00 AM
  • Firstpage
    88
  • Lastpage
    92
  • Abstract
    The structure and shape of the coils in high-voltage apparatus have a pronounced effect upon their electrical life expectancy because of the dielectric stress concentration at the edges and corners of the conductors. In these regions, as a result of the high dielectric stress, accelerated damage to the insulation can occur due to the partial discharges on the surfaces and in minute voids created during manufacture or in service. The extent of the influence of these increased stresses on the electrical life expectancy of several types of epoxy-mica insulation for large electrical machines was investigated.
  • Keywords
    "Ice","Flashover","Liquids","Insulators","Temperature measurement","Conductivity","Discharges (electric)"