Abstract :
From the testing results on the electrical breakdown phenomena of various epoxy micaceous insulations for form-wound coils of a high voltage rotating machine, electrical failure properties such as breakdown voltage and voltage endurance time were analyzed statistically using Weibull distribution.
Keywords :
"Discharges (electric)","Insulators","Flashover","Pollution","Surface contamination","Surface discharges","Stress"