• DocumentCode
    3772451
  • Title

    Statistical analysis on the electrical failure properties of the form-wound insulation systems for rotating machines

  • Author

    H. Mitsui;Y. Inoue

  • Author_Institution
    Tokyo shibaura Electric Co., Ltd. Yokohama, Japan
  • fYear
    1976
  • fDate
    6/1/1976 12:00:00 AM
  • Firstpage
    109
  • Lastpage
    113
  • Abstract
    From the testing results on the electrical breakdown phenomena of various epoxy micaceous insulations for form-wound coils of a high voltage rotating machine, electrical failure properties such as breakdown voltage and voltage endurance time were analyzed statistically using Weibull distribution.
  • Keywords
    "Discharges (electric)","Insulators","Flashover","Pollution","Surface contamination","Surface discharges","Stress"
  • Publisher
    ieee
  • Conference_Titel
    Electrical Insulation, 1976 IEEE International Conference on
  • Print_ISBN
    978-1-5090-3120-7
  • Type

    conf

  • DOI
    10.1109/EIC.1976.7464180
  • Filename