• DocumentCode
    3772452
  • Title

    Hazards of interpretation of dissipation-factor tip-up determinations

  • Author

    D.R. Johnston;N.V. Gjaja

  • Author_Institution
    General Electric Company, Schenectady, N. Y. 12345, United States
  • fYear
    1976
  • fDate
    6/1/1976 12:00:00 AM
  • Firstpage
    114
  • Lastpage
    118
  • Abstract
    Several contributions to the study of empirical correlation between tip-up and insulation life are reviewed, In addition to the published literature some previously unpublished field measurements made by the authors´ Company are cited. Some investigators report favorable correlation while others report the contrary. Our own experience on two different insulation systems indicates that the extent and the kind of correlation is dependent on the kind of insulation system which is being evaluated.
  • Keywords
    "Polymers","Aging","Temperature","Resins","Glass","Liquids","Moisture"
  • Publisher
    ieee
  • Conference_Titel
    Electrical Insulation, 1976 IEEE International Conference on
  • Print_ISBN
    978-1-5090-3120-7
  • Type

    conf

  • DOI
    10.1109/EIC.1976.7464181
  • Filename
    7464181