DocumentCode :
3772473
Title :
On the mechanism of the tree initiation
Author :
Y. Saito;M. Fukuzawa;H. Nakamura
Author_Institution :
Kyushu Industrial University, 2-327 Matsugadai, Higashi-ku, Fukuoka, JAPAN 813
fYear :
1976
fDate :
6/1/1976 12:00:00 AM
Firstpage :
209
Lastpage :
212
Abstract :
Although the initiation voltage of the tree at the needle electrode in a plastic with OC voltage is very high, a sort of tree can be formed by earthing the needle after charging it with much lower OC voltage than the initiation voltage. The tree formed by earthing will be called “earthing tree” here. Since the formation of the tree in AC field is considered as the effect of repetition of charging and discharging, some relation may exist between the AC tree and earthing tree.
Keywords :
"Insulators","Discharges (electric)","Sulfur hexafluoride","Flashover","Surface discharges","High-speed optical techniques","Optical scattering"
Publisher :
ieee
Conference_Titel :
Electrical Insulation, 1976 IEEE International Conference on
Print_ISBN :
978-1-5090-3120-7
Type :
conf
DOI :
10.1109/EIC.1976.7464202
Filename :
7464202
Link To Document :
بازگشت