DocumentCode :
3772528
Title :
Anomalous breakdown in PMMA under switching surges superimposed on direct voltage
Author :
C. Venkataseshaiah;C. Nareyana Reddy;Taher D. Eish
Author_Institution :
Department of Electrical Engineering, Indian Institute of Technology, Madras, India
fYear :
1982
fDate :
6/1/1982 12:00:00 AM
Firstpage :
127
Lastpage :
130
Abstract :
The results of experimental investigations on anomalous breakdown in polymethylmethacrylate (PMMA) immersed in transformer oil and subjected to switching surge voltages superimposed on direct voltage are reported in this paper. The anomalous breakdown voltage under such combined stresses was found to be much lower than that under direct voltage stresses alone. It is also affected by the relative polarities of the two voltages: When they are same, it increases considerably with increase in direct prestressing voltage; when they are opposite, it decreases a little. The polarity of the resultant applied voltage was also found to have effect on the distance of the anomalous breakdown location from the h.v. electrode. The duration of the superimposed switching surge (1.2/50 ?s to 1000/10000 ?s) also was found to affect the anomalous breakdown volt age. An attempt is made to explain such anomalous behaviour in modern solid synthetic insulating materials.
Keywords :
"Surges","Switches","Electric breakdown","Breakdown voltage","Surge protection","Stress","Electrodes"
Publisher :
ieee
Conference_Titel :
Electrical Insulation, 1982 IEEE International Conference on
Print_ISBN :
978-1-5090-3123-8
Type :
conf
DOI :
10.1109/EIC.1982.7464450
Filename :
7464450
Link To Document :
بازگشت