• DocumentCode
    3772563
  • Title

    Factors affecting the breakdown strength of transformer oil

  • Author

    William R. Bell;Michalis Danikas

  • Author_Institution
    Department of Electrical and Electronic Engineering, University of Newcastle upon Tyne, NE1 7RU, U.K.
  • fYear
    1982
  • fDate
    6/1/1982 12:00:00 AM
  • Firstpage
    264
  • Lastpage
    267
  • Abstract
    The a. c. breakdown strength of technical grade transformer oil is dependent on many factors. Some of the factors which have been studied in this paper are the effect of electrode area for brass and steel electrodes, the effect of gap spacing and the effect of oil velocity in the uniform field region (up to a few cm.sec?1). The phenomenon of spark conditioning has also been examined especially the effect of test cell capacitance. A few experiments have also been carried out to measure the effect of added contamination.
  • Keywords
    "Electrodes","Sparks","Steel","Oil insulation","Discharges (electric)","Impurities"
  • Publisher
    ieee
  • Conference_Titel
    Electrical Insulation, 1982 IEEE International Conference on
  • Print_ISBN
    978-1-5090-3123-8
  • Type

    conf

  • DOI
    10.1109/EIC.1982.7464485
  • Filename
    7464485